為保證示蹤線的導電性、強度、耐腐蝕和耐久性,要怎么對其進行有效的測試呢?接下來燃氣示蹤線廠家就來講講這里的相關事項。
In order to ensure the conductivity, strength, corrosion resistance and durability of the trace wire, how to effectively test it? Next, the gas pipeline trace line manufacturer will talk about the relevant matters here.
燃氣示蹤線是專為查找與定位地下非金屬管線而設計的產品,它有效地了非金屬管線不能用金屬管線尋管儀探查的問題,可廣泛適用于燃氣、供水管線管線及排水管線等地下非金屬管網的查找與定位。
Gas tracing line is a product specially designed for locating and locating underground non-metallic pipelines. It effectively solves the problem that non-metallic pipelines cannot be detected with metal pipeline finder, and can be widely used for locating and locating underground non-metallic pipelines such as gas, water supply pipelines and drainage pipelines.
示蹤線探測,管道敷設完成后,應使用管道探測器對已敷設之可探示蹤線進行可探性測試,以確保金屬絲已連接妥當,應記錄測試結果。
Tracer line detection: After the pipeline is laid, the pipeline detector shall be used to test the detectability of the laid tracers to ensure that the metal wires have been connected properly, and the test results shall be recorded.
將示蹤線的金屬線與管道定位儀的發射機輸入端連接,而發射機接地端應且盡可能遠離發射機,使用接地樁或者電線桿的接地,以減少接地電阻。用接收器去探測接受發射信號。可以找到管道位移量和埋深。
Connect the metal wire of the tracer wire with the transmitter input end of the pipe locator, and the transmitter grounding end should be as far away from the transmitter as possible. Use the grounding pile or pole grounding to reduce the grounding resistance. Use the receiver to detect and receive the transmitted signal. The displacement and buried depth of the pipeline can be found.
燃氣示蹤線
一般宜選擇截面積大于2.5毫米的多股銅質電線,鋪設時盡量讓示蹤線保持在管道的頂部位置,在三通等分支處應將導線接頭的絕緣層剝掉,把銅芯絞在一起數圈,然后用絕緣膠布裹好接頭,以保持良好的導電性;
Generally, multi strand copper wires with a sectional area of more than 2.5 mm should be selected. When laying, the trace wire should be kept at the top of the pipe as much as possible. At the tee branch, the insulation layer of the wire joint should be stripped off, the copper core twisted together for several turns, and then the joint should be wrapped with insulating tape to maintain good conductivity;
示蹤線應留有一定的線頭余量,并避免導線頭被泥土或雜物覆蓋,為減少無法出地的示蹤線末端的接地電阻,需采取剝掉絕緣層裸露芯線30cm的良好接地措施,對于采取定向鉆方式鋪設的PE管道,應選用強度更大的導線,以避免在施工中被拉斷,導致無法探測定位;
A certain amount of wire head allowance shall be reserved for the trace wire, and the wire head shall not be covered by soil or sundries. In order to reduce the grounding resistance of the end of the trace wire that cannot go out of the ground, it is necessary to take good grounding measures to strip the insulation layer to expose the core wire for 30cm. For the PE pipe laid by directional drilling, the wire with greater strength shall be selected to avoid being pulled off during construction, resulting in the inability to detect and locate;
當導線直徑遠小于埋深并忽略地介質和空氣的介質變化時,示蹤線可視為均勻介質中的一條無限。更多相關事項可以隨時來我們網站http://m.gcshome.cn咨詢了解!
When the diameter of the conductor is far less than the buried depth and the medium change of the ground medium and air is ignored, the trace line can be regarded as an infinite line in the uniform medium. More related matters can come to our website at any time http://m.gcshome.cn Ask about it!

相關產品 / Related products

  • 地釘

    地釘

  • 地釘

    地釘

  • 警示樁

    警示樁

  • 警示樁

    警示樁

截屏,微信識別二維碼

主站蜘蛛池模板: 一级做a爰片性色毛片思念网 | 欧美日韩亚洲第一页 | 成人练习生在线免费观看 | jizz日本人 | 综合久久综合 | 亚洲成人伊人网 | 亚洲国产一区视频 | 欧美在线观看禁18 | 日本免费久久久久久久网站 | 日韩大片在线观看 | 国产韩国精品一区二区三区 | 主播粉嫩国产在线精品 | 国产精品午夜电影 | 欧美日韩第一 | 久久一区二区免费播放 | 奇米第四色正能量 | 天天爱天天色天天干 | 99精品国产高清一区二区麻豆 | 叶子楣成人爽a毛片免费啪啪 | 91精品国产乱码久久久久久久久 | 九九精品99久久久香蕉 | 草草影院第一页 | 在线观看成人av | 国产网址在线 | 免费 欧美 自拍 在线观看 | 亚洲一区二区在线 | 48pao强力打造免费基地 | 亚洲国产日韩在线人高清不卡 | 国产成人高清精品免费5388 | 男女无遮挡一进一出性视频 | 久久久久欧美精品观看 | 日韩在线视频观看 | 香蕉精品视频在线观看 | 日韩欧美高清一区 | a级黄色大片在线观看视频男男 | 手机看片169 | 日本久久久免费高清 | 看黄网站在线观看 | 日本特黄特黄特刺激大片 | 亚洲免费观看网站 | 日韩精品在线免费 |